Design Criteria
Building Codes adopted effective date January 1, 2008
- 2007 California Building Code
- 2007 California Electrical Code
- 2007 California Mechanical Code
- 2007 California Plumbing Code
- 2007 California Energy Code (the same as the 2005 Building Energy Efficiency Standards)
- 1997 Uniform Housing code
- 1997 Uniform Code for the Abatement of Dangerous Building
Seismic Design
See CBC Section 1613 and ASCE 7-05 Chapter 11. Use Google, Batch Geocode (or other source) to determine site specific longitude and latitude. Use USGS website or NEHRP disk to determine S1 and Ss.
Wind Design
Basic Wind Speed (fastest mile) 80 miles per hour. Basic Wind Speed (3-second gust) 95 miles per hour. Importance factor, exposure and topographic features are site and project specific. See ASCE 7-05, Chapter 6.
Soil and Foundation
Foundation and soils investigation and reports are normally required CBC 1802.2)
Frost Depth
Minimum 12" below finished grade
Snow Loads:
The following snow loads are for City Limits of Mt. Shasta. Ground snow 62#psf — Residential Live Roof Load 60#psf / Commercial Live Roof Load 70#psf
Climate Zone
Climate Zone 16